Module RLE PL1 EXC2 OTD

Modules RLE excite

  • Dimensions in mm / inch

    Dimensions in mm / inch

Product description

  • High efficiency outdoor modules
  • Suitable for harsh and humid outdoor conditions
  • Tested acc. to salt spray test (IEC 60068-2-52) and harmful gas test (GR-1217-CORE)
  • Huge performance temperature range from -40 ... +105 °C
  • Surge tested (+/- to earth) 6 kV with Tridonic LED Driver
  • Integrated NTC for overtemperature protection
  • Additional shunts to bypass single light point failures
  • Zhaga Book 15 compliant
  • For use with standard 2x2 lenses (e.g. LEDiL Strada 2x2)
  • Push-in terminals for simple and quick wiring
  • Long life-time up to 100,000 hours
  • 8-year guarantee

Optical properties

  • Colour temperature 4,000 K
  • Typ. luminous flux 2,000 lm
  • Efficacy of the module up to 141 lm/W at 650 mA (nominal operation)
  • High colour rendering index CRI > 80
  • Small luminous flux tolerances (1)

Mechanical properties

  • Module dimension 49.5 x 121.4 mm
  • Installation of the module together with lens in the luminaire by means of an M3 screw
Autoscroll for tables
Ordering data
Type Article number Colour tempera­ture Packaging, carton Weight per pc.
RLE 2x4 2000lm 840 PL1 EXC2 OTD 89603159 4,000 K 46 pc(s). 0.027 kg
Luminaire types:
Recessed floor & wallmounted luminaires
Free-standing luminaires
Linear luminaires
Street lanterns
Wide-area luminaires (in-built, remote, pendant)
Approval marks:
ESD
cRUus
CE
ENEC
RoHs
Technical data
Beam characteristic 120°
Ambient temperature range -40 ... +80 °C
tp rated 75 °C
tc 105 °C
Irated 650 mA
Imax 1,200 mA
Max. permissible LF current ripple 1,320 mA
Max. permissible peak current 2,000 mA / max. 10 ms
Max. working voltage for insulation (1) 370 V
Max. working voltage for insulation with lens 670 V
Insulation test voltage 1.74 kV
CTI of the printed circuit board > 600
ESD classification Severity level 4
Risk group (IEC 62471) (2) RG2 (Ethr = 767 lx, RG1 at d = 50 cm)
Classification acc. to IEC 62031 Built-in
Type of protection IP00
Life-time up to 100,000 h
Autoscroll for tables
Specific technical data
Type (1) Article number Photo­metric code Typ. luminous flux at tp = 25 °C (2) Typ. luminous flux at tp = 75 °C (2) Typ. forward current Min. forward voltage at tp = 75 °C Max. forward voltage at tp = 25 °C Typ. power con­sump­tion at tp = 75 °C (2) Efficacy of the module at tp = 25 °C Luminous efficacy module at tp = 75 °C Luminous efficacy system at tp = 75 °C Col­our ren­der­ing in­dex CRI
Operating mode HE
RLE 2x4 2000lm 840 PL1 EXC2 OTD 89603159 840/579 1,890 lm 1,780 lm 500 mA 21.2 V 23.7 V 11.1 W 166 lm/W 161 lm/W 148 lm/W > 80
Operating mode NM
RLE 2x4 2000lm 840 PL1 EXC2 OTD 89603159 840/579 2,440 lm 2,300 lm 650 mA 21.5 V 24.0 V 14.6 W 163 lm/W 158 lm/W 145 lm/W > 80
Operating mode HO
RLE 2x4 2000lm 840 PL1 EXC2 OTD 89603159 840/579 3,650 lm 3,440 lm 1,050 mA 22.3 V 24.7 V 24.2 W 147 lm/W 142 lm/W 131 lm/W > 80
Document      Size       Date       
Download all selected files
 Download all selected files
Module_RLE_PL1_EXC2_OTD_en.pdf
Data sheet
1.09 MB 26/06/2020
new
Leaflet_Outdoor_EN_web.pdf
Leaflet – Outdoor
10.17 MB 26/06/2020
new
Zertifikate / Konformitätserklärung
Type      Article number      Certificates     
Certificates ()
Autoscroll for tables
CAD / RAY
Type Article number CAD Files
RLE 2x4 2000lm 840 PL1 EXC2 OTD 89603159 CAD (4.2 MB)
EPD
Type Article number Environmental Product Declaration (EPD)
RLE 2x4 2000lm 840 PL1 EXC2 OTD 89603159 EPD