Driver LCA 75W 250–750mA one4all C PRE OTD

PREMIUM outdoor series

Product description

  • Dimmable built-in constant current LED Driver
  • Output current adjustable between 250 – 750 mA via ready2mains Programmer, I-select 2 plugs or DALI
  • Max. output power 75 W
  • Power input on stand-by < 0.16 W
  • Dimming range 10 to 100 %
  • Nominal life-time up to 100,000 h
  • 5-year guarantee

Housing properties

  • Compact plastic casing
  • Type of protection IP20

Interfaces

  • one4all (DALI DT 6, DSI, switchDIM, corridorFUNCTION V2)
  • ready2mains (configuration and dimming via mains)
  • U6Me2 (configuration of chronoSTEP 2 via mains)
  • Terminal blocks: 45° / 0° push terminals

Functions

  • Adjustable output current (DALI, ready2mains, I-select 2)
  • Programmable chronoSTEP: times and levels (NFC, DALI, U6Me2, ready2mains)
  • Constant light output function (CLO)
  • Configurable via ready2mains
  • Low-temperature start feature (-40 to +70 °C temperature range)
  • Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
  • Suitable for emergency escape lighting systems acc. to EN 50172

Benefits

  • Application-oriented operating window for maximum compatibility
  • Best energy savings due to low stand-by losses and high efficiency
  • Reliability proven by life-time up to 100,000 h and 5-year guarantee
  • Flexible configuration via DALI, ready2mains, U6Me2 and I-select 2
  • In-field programming possible after installation
  • High overvoltage protection: up to 10 kV asymmetric (protection class I and II)

Typical applications

  • Road, street and industry
  • For luminaires of protection class I and protection class II
Autoscroll for tables
Ordering data
Type Article number (1) Pack­ag­ing, carton Pack­ag­ing, pallet Pack­ag­ing, high volume Weight per pc.
LCA 75W 250-750mA one4all C PRE OTD 28001072 10 pc(s). 390 pc(s). 0.588 kg
LCA 75W 250-750mA one4all C PRE OTD 87500664 10 pc(s). 260 pc(s). 1,040 pc(s). 0.554 kg
Luminaire types:
Street lanterns
Approval marks:
DALI-2
130
Short Circuit Proof without safety insulation
doppelte Isolierung
r2m
Emergency Lighting suitable
EAC
CCC
RCM
CE
ENEC
RoHs
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. current (at 230 V, 50 Hz, full load) (1) (2) 177 – 363 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) 50 – 78 mA
Leakage current (at 230 V, 50 Hz, full load) (1) (2) < 300 µA
Max. input power 81.9 W
Typ. efficiency (at 230 V, 50 Hz, full load) (2) 93 %
λ (at 230 V, 50 Hz, full load) (1) 0.99C
Typ. power input on stand-by (3) < 0.16 W
In-rush current (peak / duration) 37 A / 235 µs
THD (at 230 V, 50 Hz, full load) (1) < 5 %
Time to light (at 230 V, 50 Hz, full load) (1) < 280 ms
Time to light (DC mode) < 280 ms
Switchover time (AC/DC) < 150 ms
Turn off time (at 230 V, 50 Hz, full load) < 20 ms
Output current tolerance (1) (4) ± 3 %
Max. output current peak (non-repetitive) ≤ output current + 40 %
Output LF current ripple (< 120 Hz) ± 5 %
Max. output voltage (U-OUT) 250 V
Dimming range 10 – 100 %
Mains surge capability (between L - N) (5) 6 kV / 3,000 A
Mains surge capability (between L/N - PE) 6 kV
Mains surge capability up to (between L/N - PE) without DALI connection 10 kV
Burst protection (6) 6 kV
Surge voltage at output side (against PE) < 500 V
Type of protection IP54
Dimensions L x W x H 133 x 77 x 40 mm
Autoscroll for tables
Specific technical data
Type Output current (1) Min. forward voltage Max. for­ward volt­age Max. output power Typ. power con­sump­tion (at 230 V, 50 Hz, full load) Typ. current consumption (at 230 V, 50 Hz, full load) tc point max. Ambient temperature ta I-select 2 resistor value (2)
LCA 75W 250-750mA one4all C PRE OTD 250 mA 45 V 130 V 32.5 W 39.3 W 177 mA 85 °C -40 ... +65 °C
LCA 75W 250-750mA one4all C PRE OTD 275 mA 45 V 130 V 35.8 W 42.5 W 191 mA 85 °C -40 ... +65 °C 18.18 kΩ
LCA 75W 250-750mA one4all C PRE OTD 300 mA 45 V 130 V 39.0 W 45.7 W 204 mA 85 °C -40 ... +65 °C 16.67 kΩ
LCA 75W 250-750mA one4all C PRE OTD 325 mA 45 V 130 V 42.3 W 49.0 W 219 mA 85 °C -40 ... +65 °C 15.38 kΩ
LCA 75W 250-750mA one4all C PRE OTD 350 mA 45 V 130 V 45.5 W 52.2 W 232 mA 85 °C -40 ... +65 °C 14.29 kΩ
LCA 75W 250-750mA one4all C PRE OTD 375 mA 45 V 130 V 48.8 W 55.7 W 247 mA 85 °C -40 ... +65 °C 13.33 kΩ
LCA 75W 250-750mA one4all C PRE OTD 400 mA 45 V 130 V 52.0 W 58.9 W 261 mA 85 °C -40 ... +65 °C 12.50 kΩ
LCA 75W 250-750mA one4all C PRE OTD 425 mA 45 V 130 V 55.3 W 62.1 W 275 mA 85 °C -40 ... +60 °C 11.76 kΩ
LCA 75W 250-750mA one4all C PRE OTD 450 mA 45 V 130 V 58.5 W 65.3 W 288 mA 85 °C -40 ... +60 °C 11.11 kΩ
LCA 75W 250-750mA one4all C PRE OTD 475 mA 45 V 130 V 61.8 W 68.5 W 303 mA 85 °C -40 ... +60 °C 10.53 kΩ
LCA 75W 250-750mA one4all C PRE OTD 500 mA 45 V 130 V 65.0 W 71.9 W 316 mA 85 °C -40 ... +60 °C 10.00 kΩ
LCA 75W 250-750mA one4all C PRE OTD 525 mA 45 V 130 V 68.3 W 75.2 W 330 mA 85 °C -40 ... +60 °C 9.52 kΩ
LCA 75W 250-750mA one4all C PRE OTD 550 mA 45 V 130 V 71.5 W 78.4 W 345 mA 85 °C -40 ... +60 °C 9.09 kΩ
LCA 75W 250-750mA one4all C PRE OTD 575 mA 45 V 130 V 74.8 W 81.9 W 360 mA 85 °C -40 ... +60 °C 8.70 kΩ
LCA 75W 250-750mA one4all C PRE OTD 600 mA 45 V 125 V 75.0 W 81.6 W 362 mA 85 °C -40 ... +60 °C 8.33 kΩ
LCA 75W 250-750mA one4all C PRE OTD 625 mA 45 V 120 V 75.0 W 81.5 W 362 mA 80 °C -40 ... +60 °C 8.00 kΩ
LCA 75W 250-750mA one4all C PRE OTD 650 mA 45 V 115 V 75.0 W 81.0 W 361 mA 80 °C -40 ... +60 °C 7.69 kΩ
LCA 75W 250-750mA one4all C PRE OTD 675 mA 45 V 111 V 75.0 W 81.0 W 360 mA 85 °C -40 ... +65 °C 7.41 kΩ
LCA 75W 250-750mA one4all C PRE OTD 700 mA 45 V 107 V 75.0 W 81.0 W 359 mA 85 °C -40 ... +65 °C 7.14 kΩ
LCA 75W 250-750mA one4all C PRE OTD 725 mA 45 V 103 V 75.0 W 80.9 W 359 mA 85 °C -40 ... +65 °C 6.90 kΩ
LCA 75W 250-750mA one4all C PRE OTD 750 mA 45 V 100 V 75.0 W 81.0 W 360 mA 85 °C -40 ... +65 °C 6.67 kΩ
Document      Size       Date       
Download all selected files
 Download all selected files
TALEXXdriver_LCA_75W_250-750mA_one4all_C_PRE_OTD_en.pdf
Data sheet
1.53 MB 31/08/2018
new
LCA_PRE_OTD_Product_Manual_en.pdf
Driver LCA PRE OTD – Product Manual
1.9 MB 02/03/2018
Instruction_manual_U6Me2_programming_en.pdf
U6Me2 programming – Instruction manual
1020 KB 30/06/2017
Leaflet_Outdoor_EN_web.pdf
Leaflet – Outdoor
1.71 MB 01/10/2018
new
Zertifikate / Konformitätserklärung
Type      Article number      Certificates     
Certificates ()

I-SELECT 2 PLUG PRE / EXC Accessories

Product description

  • Ready-for-use resistor to set output current value
  • Compatible with LED Driver featuring I-select 2 interface; not compatible with I-select (generation 1)
  • Resistor is base isolated
  • Resistor power 0.25 W
  • Current tolerance ± 2 % additional to output current tolerance
  • Compatible with LED Driver series PRE and EXC

Example of calculation

  • R [kΩ] = 5 V / I_out [mA] x 1000
  • Resistor value tolerance ≤ 1 %; resistor power ≥ 0.1 W; base isolation necessary
Ordering data
Type Article number Colour Marking Current Resistor value Pack­ag­ing, bag Weight per pc.
I-SELECT 2 PLUG 250MA BL 28001106 Blue 0250 mA 250 mA 20.00 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 275MA BL 28001107 Blue 0275 mA 275 mA 18.18 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 300MA BL 28001108 Blue 0300 mA 300 mA 16.67 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 325MA BL 28001109 Blue 0325 mA 325 mA 15.38 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 350MA BL 28001110 Blue 0350 mA 350 mA 14.29 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 375MA BL 28001111 Blue 0375 mA 375 mA 13.33 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 400MA BL 28001112 Blue 0400 mA 400 mA 12.50 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 425MA BL 28001251 Blue 0425 mA 425 mA 11.76 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 450MA BL 28001113 Blue 0450 mA 450 mA 11.11 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 475MA BL 28001252 Blue 0475 mA 475 mA 10.53 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 500MA BL 28001114 Blue 0500 mA 500 mA 10.00 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 525MA BL 28001960 Blue 0525 mA 525 mA 9.52 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 550MA BL 28001115 Blue 0550 mA 550 mA 9.09 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 600MA BL 28001116 Blue 0600 mA 600 mA 8.33 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 650MA BL 28001117 Blue 0650 mA 650 mA 7.69 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 700MA BL 28001118 Blue 0700 mA 700 mA 7.14 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 750MA BL 28001119 Blue 0750 mA 750 mA 6.67 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG Deactivation 28001462 Blue CHRO OFF 0.001 kg
Autoscroll for tables
CAD / RAY
Type Article number (1) CAD Files
LCA 75W 250-750mA one4all C PRE OTD 28001072 CAD (572.9 KB)
LCA 75W 250-750mA one4all C PRE OTD 87500664 CAD (572.9 KB)
EPD
Type Article number (1) Environmental Product Declaration (EPD)
LCA 75W 250-750mA one4all C PRE OTD 28001072 EPD