Driver LC 50W 100–400mA 140V po4a NF h16 PRE3 NEW

premium series non-SELV

Product description

  • Dimmable built-in constant current LED Driver
  • Adjustable output current between 100 and 400 mA via NFC, DALI, I-select 2 Plugs or ready2mains
  • Max. output power 50 W
  • Up to 89 % efficiency
  • Power input on stand-by < 0.2 W
  • Dimming range 1 to 100 %
  • For luminaires of protection class I and protection class II
  • Nominal life-time up to 100,000 h
  • 5-year guarantee

Housing properties

  • Low profile metal casing with white cover
  • Type of protection IP20
  • Only 16 mm housing height

Interfaces

  • Near field communication (NFC)
  • one4all (DALI-2 DT 6, DSI, switchDIM, corridorFUNCTION)
  • ready2mains (configuration and dimming via mains)
  • Terminal blocks: 0° push terminals

Functions

  • Adjustable output current (NFC, DALI, I-select 2, ready2mains)
  • Integrated DALI bus voltage power supply
  • Constant light output function (CLO)
  • Power-up fading at AC
  • Configurable via ready2mains
  • Service monitor to log certain events
  • Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
  • Suitable for emergency escape lighting systems acc. to EN 50172

Benefits

  • Application-oriented operating window for maximum compatibility
  • Best energy savings due to low stand-by losses and high efficiency

Typical applications

  • For linear/area lighting in office applications
Autoscroll for tables
Ordering data
Type Article number Pack­ag­ing, carton Pack­ag­ing, pallet Weight per pc.
LC 50/100-400/140 po4a NF h16 PRE 28002372 10 pc(s). 760 pc(s). 0.208 kg
Luminaire types:
Free-standing luminaires
Linear luminaires
Wide-area luminaires (in-built, remote, pendant)
Approval marks:
NFC
DALI-2
IP20
Short Circuit Proof Base Isolation
110
r2m
Emergency Lighting suitable
EAC
RCM
CE
ENEC
RoHs
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. rated current (at 230 V, 50 Hz, full load) (1) (2) 247 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) 53 mA
Leakage current (PE) < 330 µA
Max. input power 56 W
Typ. efficiency (at 230 V, 50 Hz, full load) (2) 89 %
λ (at 230 V, 50 Hz, full load) (1) 0.99C
Typ. power input on stand-by (3) < 0.2 W
Typ. input current in no-load operation 17 mA
Typ. input power in no-load operation 0.6 W
In-rush current (peak / duration) 24.7 A / 175 µs
THD (at 230 V, 50 Hz, full load) (1) < 4.6 %
Starting time (AC mode) < 0.6 s
Starting time (DC mode) < 0.3 s
Switchover time (AC/DC) < 0.3 s
Turn off time (at 230 V, 50 Hz, full load) < 18 ms
Output current tolerance (1) ± 3 %
Max. output current peak (non-repetitive) ≤ output current + 15 %
Output LF current ripple (< 120 Hz) ± 3 %
Max. output voltage (U-OUT) 250 V
Dimming range 1 – 100 %
Mains surge capability (between L - N) 1 kV
Mains surge capability (between L/N - PE) 2 kV
Surge voltage at output side (against PE) < 500 V
Type of protection IP20
Dimensions L x W x H 360 x 30 x 16 mm
Autoscroll for tables
Specific technical data
Type Output current (1) Min. forward voltage Max. for­ward volt­age Max. output power Typ. power con­sump­tion (at 230 V, 50 Hz, full load) Typ. current consumption (at 230 V, 50 Hz, full load) tc point max. Ambient temperature ta I-select 2 resistor value (2)
LC 50/100-400/140 po4a NF h16 PRE 100 mA 50 V 140 V 14.0 W 19.0 W 89 mA 80 °C -25 ... +55 °C
LC 50/100-400/140 po4a NF h16 PRE 125 mA 50 V 140 V 17.5 W 22.5 W 104 mA 80 °C -25 ... +55 °C 40.00 kΩ
LC 50/100-400/140 po4a NF h16 PRE 150 mA 50 V 140 V 21.0 W 26.2 W 119 mA 80 °C -25 ... +55 °C 33.33 kΩ
LC 50/100-400/140 po4a NF h16 PRE 175 mA 50 V 140 V 24.5 W 29.8 W 134 mA 80 °C -25 ... +55 °C 28.75 kΩ
LC 50/100-400/140 po4a NF h16 PRE 200 mA 50 V 140 V 28.0 W 33.4 W 149 mA 80 °C -25 ... +55 °C 25.00 kΩ
LC 50/100-400/140 po4a NF h16 PRE 225 mA 50 V 140 V 31.5 W 37.1 W 165 mA 80 °C -25 ... +50 °C 22.22 kΩ
LC 50/100-400/140 po4a NF h16 PRE 250 mA 50 V 140 V 35.0 W 40.7 W 181 mA 80 °C -25 ... +50 °C 20.00 kΩ
LC 50/100-400/140 po4a NF h16 PRE 275 mA 50 V 140 V 38.5 W 44.4 W 196 mA 80 °C -25 ... +50 °C 18.18 kΩ
LC 50/100-400/140 po4a NF h16 PRE 300 mA 50 V 140 V 42.0 W 48.1 W 212 mA 80 °C -25 ... +50 °C 16.66 kΩ
LC 50/100-400/140 po4a NF h16 PRE 325 mA 50 V 140 V 45.5 W 51.7 W 228 mA 80 °C -25 ... +50 °C 15.38 kΩ
LC 50/100-400/140 po4a NF h16 PRE 350 mA 50 V 140 V 49.0 W 55.4 W 244 mA 80 °C -25 ... +50 °C 14.28 kΩ
LC 50/100-400/140 po4a NF h16 PRE 375 mA 50 V 133 V 49.0 W 56.2 W 247 mA 80 °C -25 ... +50 °C 13.33 kΩ
LC 50/100-400/140 po4a NF h16 PRE 400 mA 50 V 125 V 50.0 W 56.1 W 247 mA 80 °C -25 ... +50 °C 0.00 kΩ
Document      Size       Date       
Download all selected files
 Download all selected files
Driver_LC_50W_100-400mA_140V_po4a_NF_h16_PRE3_en.pdf
Data sheet
1.24 MB 20/12/2018
new
Leaflet_Driver_EN_web.pdf
Leaflet – LED Drivers
7.73 MB 03/12/2018
new
Zertifikate / Konformitätserklärung
Type      Article number      Certificates     
Certificates ()

I-SELECT 2 PLUG PRE / EXC Accessories

Product description

  • Ready-for-use resistor to set output current value
  • Compatible with LED Driver featuring I-select 2 interface; not compatible with I-select (generation 1)
  • Resistor is base isolated
  • Resistor power 0.25 W
  • Current tolerance ± 2 % additional to output current tolerance
  • Compatible with LED Driver series PRE and EXC

Example of calculation

  • R [kΩ] = 5 V / I_out [mA] x 1000
  • Resistor value tolerance ≤ 1 %; resistor power ≥ 0.1 W; base isolation necessary
  • When using a resistor value beyond the specified range, the output current will automatically be set to the minimum value (resistor value too big), respectively to the maximum value (resistor value too small)
Ordering data
Type Article number Colour Marking Current Resistor value Pack­ag­ing, bag Weight per pc.
I-SELECT 2 PLUG 125MA BL 28001101 Blue 0125 mA 125 mA 40.20 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 150MA BL 28001102 Blue 0150 mA 150 mA 33.20 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 175MA BL 28001103 Blue 0175 mA 175 mA 28.70 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 200MA BL 28001104 Blue 0200 mA 200 mA 24.90 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 225MA BL 28001105 Blue 0225 mA 225 mA 22.10 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 250MA BL 28001106 Blue 0250 mA 250 mA 20.00 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 275MA BL 28001107 Blue 0275 mA 275 mA 18.20 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 300MA BL 28001108 Blue 0300 mA 300 mA 16.50 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 325MA BL 28001109 Blue 0325 mA 325 mA 15.40 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 375MA BL 28001111 Blue 0375 mA 375 mA 13.30 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 400MA BL 28001112 Blue 0400 mA 400 mA 12.40 kΩ 10 pc(s). 0.001 kg
I-SELECT 2 PLUG MAX BL 28001099 Blue MAX MAX 0.00 kΩ 10 pc(s). 0.001 kg
Autoscroll for tables
EPD
Type Article number Environmental Product Declaration (EPD)
LC 50/100-400/140 po4a NF h16 PRE 28002372 EPD