Driver LCA 60W 350–1050mA one4all C PRE OTD

PREMIUM outdoor series

Product description

  • Dimmable built-in constant current LED Driver
  • Output current adjustable between 350 – 1,050 mA via ready2mains Programmer, I-select 2 plugs or DALI
  • Max. output power 60 W
  • Power input on stand-by < 0.16 W
  • Dimming range 10 to 100 %
  • Nominal life-time up to 100,000 h
  • 5-year guarantee

Housing properties

  • Compact plastic casing
  • Type of protection IP20

Interfaces

  • one4all (DALI DT 6, DSI, switchDIM, corridorFUNCTION V2)
  • ready2mains (configuration and dimming via mains)
  • U6Me2 (configuration of chronoSTEP 2 via mains)
  • Terminal blocks: 45° / 0° push terminals

Functions

  • Adjustable output current (DALI, ready2mains, I-select 2)
  • Programmable chronoSTEP: times and levels (DALI, U6Me2, ready2mains)
  • Constant light output function (CLO)
  • Configurable via ready2mains
  • Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
  • Suitable for emergency escape lighting systems acc. to EN 50172

Benefits

  • Application-oriented operating window for maximum compatibility
  • Best energy savings due to low stand-by losses and high efficiency
  • Reliability proven by life-time up to 100,000 h and 5-year guarantee
  • Flexible configuration via DALI, ready2mains, U6Me2 and I-select 2
  • In-field programming possible after installation
  • High overvoltage protection: up to 10 kV asymmetric (protection class I and II)

Typical applications

  • Road, street and industry
  • For luminaires of protection class I and protection class II
Autoscroll for tables
Ordering data
Type Article number Pack­ag­ing, carton Pack­ag­ing, pallet Weight per pc.
LCA 60W 350-1050mA one4all C PRE OTD 28001071 10 pc(s). 390 pc(s). 0.545 kg
Luminaire types:
Street lanterns
Approval marks:
SELV
130
Short Circuit Proof without safety insulation
doppelte Isolierung
r2m
EL
EAC
KC
RCM
CE
ENEC
RoHs
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. current (at 230 V, 50 Hz, full load) (1) (2) 155 – 289 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) 51 – 63 mA
Leakage current (at 230 V, 50 Hz, full load) (1) (2) < 300 µA
Max. input power 66 W
Typ. efficiency (at 230 V, 50 Hz, full load) (2) 93 %
λ (at 230 V, 50 Hz, full load) (1) 0.99
Typ. power input on stand-by (3) < 0.16 W
In-rush current (peak / duration) 37 A / 233 µs
THD (at 230 V, 50 Hz, full load) (1) < 16 %
Time to light (at 230 V, 50 Hz, full load) (1) < 300 ms
Time to light (DC mode) < 300 ms
Switchover time (AC/DC) < 150 ms
Turn off time (at 230 V, 50 Hz, full load) < 20 ms
Output current tolerance (1) (4) ± 2 %
Max. output current peak (non-repetitive) ≤ output current + 40 %
Output LF current ripple (< 120 Hz) ± 5 %
Max. output voltage 120 V
Dimming range 10 – 100 %
Mains surge capability (between L - N) (5) 6 kV / 3,000 A
Mains surge capability (between L/N - PE) 6 kV
Mains surge capability (between L/N - PE) without DALI connection 8 kV
Burst protection (6) 6 kV
Surge voltage at output side (against PE) < 500 V
Dimensions L x W x H 133 x 77 x 40 mm
Autoscroll for tables
Specific technical data
Type Output current (1) Min. forward voltage Max. for­ward volt­age Max. output power Typ. power con­sump­tion (at 230 V, 50 Hz, full load) Typ. current consumption (at 230 V, 50 Hz, full load) tc point max. Ambient temperature ta I-select 2 resistor value (2)
LCA 60W 350-1050mA one4all C PRE OTD 350 mA 30 V 85 V 29.8 W 35.0 W 155 mA 80 °C -30 ... +70 °C
LCA 60W 350-1050mA one4all C PRE OTD 400 mA 30 V 85 V 34.0 W 39.3 W 174 mA 80 °C -30 ... +70 °C 12.50 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 450 mA 30 V 85 V 38.3 W 43.6 W 192 mA 80 °C -30 ... +70 °C 11.11 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 500 mA 30 V 85 V 42.5 W 47.9 W 211 mA 80 °C -30 ... +70 °C 10.00 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 550 mA 30 V 85 V 46.8 W 52.3 W 230 mA 85 °C -30 ... +70 °C 9.09 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 600 mA 30 V 85 V 51.0 W 56.7 W 249 mA 85 °C -30 ... +70 °C 8.33 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 650 mA 30 V 85 V 55.3 W 61.1 W 267 mA 85 °C -30 ... +70 °C 7.69 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 700 mA 30 V 85 V 59.5 W 65.7 W 288 mA 85 °C -30 ... +70 °C 7.14 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 750 mA 30 V 80 V 60.0 W 66.0 W 289 mA 85 °C -30 ... +70 °C 6.67 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 800 mA 30 V 75 V 60.0 W 65.9 W 288 mA 85 °C -30 ... +70 °C 6.25 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 850 mA 30 V 71 V 60.0 W 66.0 W 289 mA 85 °C -30 ... +70 °C 5.88 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 900 mA 30 V 67 V 60.0 W 65.7 W 288 mA 80 °C -30 ... +70 °C 5.56 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 950 mA 30 V 63 V 60.0 W 65.6 W 287 mA 80 °C -30 ... +70 °C 5.26 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 1,000 mA 30 V 60 V 60.0 W 65.8 W 288 mA 80 °C -30 ... +70 °C 5.00 kΩ
LCA 60W 350-1050mA one4all C PRE OTD 1,050 mA 30 V 57 V 60.0 W 66.0 W 289 mA 80 °C -30 ... +70 °C 4.76 kΩ
Document      Size       Date       
Download all selected files Download all selected files
TALEXXdriver_LCA_60W_350-1050mA_one4all_C_PRE_OTD_en.pdf
Data sheet
1.50 MB 06/12/2016
new
LCA_PRE_LC_EXC_ProductManual_en.pdf
Driver LCA PRE / LC EXC – Product manual
4.86 MB 08/06/2016
chronoSTEP_Manual_en.pdf
chronoSTEP 2 Instruction manual
1.05 MB 22/12/2015
Leaflet_Outdoor_EN_web.pdf
Leaflet – Outdoor
1.13 MB 06/10/2016
Zertifikate / Konformitätserklärung
Type      Article number      Certificates     
Certificates ()

I-SELECT 2 PLUG PRE / EXC Accessories

Product description

  • Ready-for-use resistor to set output current value
  • Compatible with LED Driver featuring I-select 2 interface; not compatible with I-select (generation 1)
  • Resistor is base isolated
  • Resistor power 0.25 W
  • Current tolerance ± 2 % additional to output current tolerance
  • Compatible with LED Driver series PRE and EXC

Example of calculation

  • R [kΩ] = 5 V / I_out [mA] x 1000
  • Resistor value tolerance ≤ 1 %; resistor power ≥ 0.1 W; base isolation necessary
  • When using a resistor value beyond the specified range, the output current will automatically be set to the minimum value (resistor value too big), respectively to the maximum value (resistor value too small)
Ordering data
Type Article number Colour Marking Current Pack­ag­ing, bag Weight per pc.
I-SELECT 2 PLUG 350MA BL 28001110 Blue 0350 mA 350 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 375MA BL 28001111 Blue 0375 mA 375 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 400MA BL 28001112 Blue 0400 mA 400 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 425MA BL 28001251 Blue 0425 mA 425 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 450MA BL 28001113 Blue 0450 mA 450 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 475MA BL 28001252 Blue 0475 mA 475 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 500MA BL 28001114 Blue 0500 mA 500 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 550MA BL 28001115 Blue 0550 mA 550 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 600MA BL 28001116 Blue 0600 mA 600 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 650MA BL 28001117 Blue 0650 mA 650 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 700MA BL 28001118 Blue 0700 mA 700 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 750MA BL 28001119 Blue 0750 mA 750 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 800MA BL 28001120 Blue 0800 mA 800 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 850MA BL 28001121 Blue 0850 mA 850 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 900MA BL 28001122 Blue 0900 mA 900 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 950MA BL 28001123 Blue 0950 mA 950 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 1000MA BL 28001124 Blue 1000 mA 1,000 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG 1050MA BL 28001125 Blue 1050 mA 1,050 mA 10 pc(s). 0.001 kg
I-SELECT 2 PLUG Deactivation 28001462 Blue CHRO OFF 0.001 kg
Autoscroll for tables
CAD / RAY
Type Article number CAD Files
LCA 60W 350-1050mA one4all C PRE OTD 28001071 CAD (572.9 KB)
EPD
Type Article number Environmental Product Declaration (EPD)
LCA 60W 350-1050mA one4all C PRE OTD 28001071 EPD

Please choose one of the following modules

Autoscroll for tables
Ordering data
Type Article number Configuration